Port configuration
The PinPad serial/usb port is configured in the PinPadShared section, Port field.
[PinPadShared]
Porta=<PORT>
In Windows, you must use the serial/usb port number. Per example: 12
In Linux, you must indicate the full path of the device. For example: /dev/ttyS1 or /dev/ttyACM0
As of CliSiTef version 4.0.111.3 for Windows and 4.0.111.18 for Linux, you can use the 'AUTO_USB' value to identify automatically port a USB pinpad.
[PinPadShared]
Porta=AUTO_USB
Note: the above configuration is only valid for the Windows platform 32 and Linux 32 (starting with kernel 2.6), in the versions mentioned above.
Pinpads that support the AUTO_USB configuration in a WINDOWS environment:
Manufacturer/Model | CliSiTef Minimum Version |
---|---|
Gertec PPC900, PPC910, PPC920 e PPC930 | 4.0.111.3 |
Ingenico iCT2xx | 4.0.111.3 |
Ingenico iHT1, iHT2, iHT3, iHT4 e iHT5 | 4.0.111.3 |
Ingenico IPPxxx | 4.0.111.3 |
Ingenico iSC2xx | 4.0.111.3 |
Ingenico iSC350 | 4.0.111.3 |
Ingenico iST1xx | 4.0.111.3 |
Ingenico iUC1xx | 4.0.111.3 |
Ingenico iUP250 | 4.0.111.3 |
Ingenico Lane3000 | 6.2.115.17 r1 |
PAX D200 | 4.0.111.3 |
Verifone Vx810 e Vx820 | 4.0.111.3 |
Verifone P200 | 6.2.115.28 r2 |
Pinpads that support the AUTO_USB configuration in a LINUX environment:
Manufacturer/Model | CliSiTef Minimum Version |
---|---|
Gertec PPC900, PPC910 e PPC920 | 4.0.111.18 |
Ingenico iCT2xx | 4.0.111.18 |
Ingenico iHT1, iHT2, iHT3, iHT4 e iHT5 | 4.0.111.18 |
Ingenico IPPxxx | 4.0.111.18 |
Ingenico iSC2xx | 4.0.111.18 |
Ingenico iSC350 | 4.0.111.18 |
Ingenico iST1xx | 4.0.111.18 |
Ingenico iUC1xx | 4.0.111.18 |
Ingenico iUP250 | 4.0.111.18 |
Verifone Vx810 e Vx820 | 4.0.111.18 |
Note: Pinpads from new manufacturers or new models may be included in the lists above in the future.