PinPad configuration
#
Port ConfigurationThe PinPad serial/USB port is configured in the PinpadCompartilized section, door field.
In Windows, you must use the serial/usb port number. For example: 12
In Linux, you must indicate the full path of the device. For example: /dev/ttyS1 or /dev/ttyACM0
Starting with CliSiTef version 4.0.111.3 for Windows and 4.0.111.18 for Linux, it is possible to use the value ‘AUTO_USB’ to automatically identify the port of a USB pinpad.
Note: the above configuration is only valid for Windows 32 and Linux 32 platforms (from kernel 2.6 onwards), in the versions mentioned above.
Pinpads that support the AUTO_USB configuration in a WINDOWS environment:
Manufacturer/Model | CliSITef Minimum Version |
---|---|
Gertec PPC900, PPC910, PPC920 and PPC930 | 4.0.111.3 |
Ingenico iCT2xx | 4.0.111.3 |
Ingenico iHT1, iHT2, iHT3, iHT4 and iHT5 | 4.0.111.3 |
Ingenico IPPxxx | 4.0.111.3 |
Ingenico iSC2xx | 4.0.111.3 |
Ingenico iSC350 | 4.0.111.3 |
Ingenico iST1xx | 4.0.111.3 |
Ingenico iUC1xx | 4.0.111.3 |
Ingenico iUP250 | 4.0.111.3 |
Ingenico Lane3000 | 6.2.115.17 r1 |
PAX D200 | 4.0.111.3 |
Verifone Vx810 and Vx820 | 4.0.111.3 |
Verifone P200 | 6.2.115.28 r2 |
Pinpads that support the AUTO_USB configuration in a LINUX environment:
Manufacturer/Model | CliSiTef Minimum Version |
---|---|
Gertec PPC900, PPC910 and PPC920 | 4.0.111.18 |
Ingenico iCT2xx | 4.0.111.18 |
Ingenico iHT1, iHT2, iHT3, iHT4 and iHT5 | 4.0.111.18 |
Ingenico IPPxxx | 4.0.111.18 |
Ingenico iSC2xx | 4.0.111.18 |
Ingenico iSC350 | 4.0.111.18 |
Ingenico iST1xx | 4.0.111.18 |
Ingenico iUC1xx | 4.0.111.18 |
Ingenico iUP250 | 4.0.111.18 |
Verifone Vx810 and Vx820 | 4.0.111.18 |
Note: Pinpads from new manufacturers or new models may be included in the lists above in the future.